1HP Commercial Hot & Cold Plunge Chiller | SVA-10D
1HP 220–240V commercial hot and cold plunge chiller with 3100W cooling, 3600W heating and 20 L/min circulation for gyms and recovery studios.
HorsePower
1HP
Power Supply
AC 220–240V, 50/60Hz
Temperature Range
0℃–42℃ (32°F–107.6°F)
Total Input Power
1162W
仕様
| HorsePower | 1HP |
| Power Supply | AC 220–240V, 50/60Hz |
| Temperature Range | 0℃–42℃ (32°F–107.6°F) |
| Total Input Power | 1162W |
| Cooling Capacity | 3100W |
| Heating Capacity | 3600W |
| Circulated Flow Rate | 20 L/min |
| Temperature Variance | ±0.5°C precision control |
| Net Weight | 38 kg |
| Refrigerant | R32 (330 g) |
| Dimensions | 535 × 348 × 516 mm |
| Packing Dimensions | 690 × 515 × 670 mm |
主な特徴
- Commercial 1HP Hot & Cold Platform: Delivers 3100W cooling and 3600W heating for properly sized plunge tubs in gyms, recovery studios and wellness facilities.
- 20 L/min Integrated Circulation: Maintains continuous water movement through the chiller and filtration loop for stable temperature control.
- Built for Frequent Commercial Operation: Durable modular construction and accessible service areas help reduce maintenance downtime during long operating schedules.
- Integrated Filtration Connections: Rear cartridge filtration, clearly marked inlet and outlet ports and accessible plumbing support a practical water-care workflow.
- Portable Wheeled Design: Integrated carry handles and transport wheels make repositioning, cleaning and service access easier.
- OEM/ODM Project Support: Configure branding, enclosure finish, labels, documentation, 220–240V plug type and packaging for distributor or facility projects.
1HP Commercial Ice Bath Chiller for High-Use Recovery Facilities
The Springvive SVA-10D is a 1HP commercial hot and cold plunge chiller designed for gyms, recovery studios, sports clubs, clinics, spas and OEM wellness projects. The 220–240V configuration combines 3100W cooling capacity, 3600W heating capacity, 20 L/min circulated flow, a 0°C–42°C rated temperature range and ±0.5°C digital temperature control in a compact wheeled enclosure.
The system is intended for operators who need repeatable temperature control without relying on daily ice deliveries. Actual pull-down and recovery time depends on water volume, starting and target temperatures, ambient heat, tub insulation, cover use, plumbing length, circulation rate and the number of users per hour. Provide the real installation conditions for a project-specific sizing check.
Why Choose the SVA-10D Commercial Plunge Chiller?
3100W Cooling and 3600W Heating
The 1HP 220–240V configuration provides 3100W rated cooling capacity and 3600W rated heating capacity. This supports both cold-plunge and warm-water recovery programs, while final suitability must still be checked against the actual water volume, ambient temperature and required recovery time.
Cooling and Heating in One System
The rated 0°C–42°C control range supports cold-plunge sessions and warm-water recovery programs. A 20 L/min circulation loop moves water through the chiller and filtration circuit, while the digital controller maintains the selected setpoint with ±0.5°C precision. Confirm the final minimum operating setpoint, freeze-protection settings and water-care requirements in the supplied manual.
Designed for Frequent Commercial Operation
A metal enclosure, accessible ventilation panels and modular service areas support long operating schedules and routine maintenance. Commercial duty should be assessed using opening hours, users per hour, recovery targets and the facility's cleaning workflow rather than horsepower alone.
Integrated Filtration and Accessible Plumbing
The rear service area includes cartridge filtration and clearly marked inlet and outlet connections. This layout supports visible inspection, filter service and a documented water-care routine. Filtration does not replace regular cleaning, approved water treatment or water changes based on user load.
Portable and Service-Friendly
Carry handles, transport wheels and a compact 535 × 348 × 516 mm body make the unit easier to position near a plunge tub. Keep all ventilation openings clear and leave the service side accessible when planning the installation.
OEM/ODM Support for B2B Projects
Springvive can discuss logo placement, enclosure finish, controller language, labels, manual language, carton artwork, voltage, plug type and other project requirements. Availability, tooling, MOQ, sampling cost and lead time depend on the approved specification.
Technical Specifications
| Specification | Verified product data |
|---|---|
| Model | SVA-10D |
| Product type | Commercial hot and cold ice bath chiller |
| Power configuration | 1HP |
| Power supply | AC 220–240V, 50/60Hz |
| Total input power | 1162W |
| Cooling capacity | 3100W |
| Heating capacity | 3600W |
| Circulated flow rate | 20 L/min |
| Rated temperature range | 0°C–42°C (32°F–107.6°F) |
| Temperature control | ±0.5°C |
| Refrigerant | R32 (330 g) |
| Functions | Cooling, heating, circulation and cartridge filtration |
| Product dimensions | 535 × 348 × 516 mm |
| Net weight | 38 kg |
| Packing dimensions | 690 × 515 × 670 mm |
| Control | Digital temperature controller |
| Mobility | Carry handles and transport wheels |
1HP Performance Curve for a 300 L Plunge
Under the supplied calculation conditions—300 L of water and 25°C ambient temperature—the estimated cooling time from 25°C to 5°C is approximately 3.7 hours. The reverse heating cycle from 5°C to 25°C is approximately 2.7 hours.

Performance note: The curve is calculated from the supplied endpoints and total times. Intermediate points are illustrative. Actual performance varies with water volume, insulation, cover use, plumbing length, circulation, ambient heat and user load.
Commercial Selection and Sizing Guide
| Application | Information required | Selection priority | Recommended action |
|---|---|---|---|
| Gym or recovery studio | Water volume, users per hour, opening hours and target temperature | Peak-hour recovery and service access | Request a commercial heat-load check |
| Sports club or training center | Session schedule, tub insulation and turnaround time | Consistent temperature between groups | Confirm recovery time under peak use |
| Spa or clinic | Cold/warm program, sanitation workflow and room ventilation | Temperature range, hygiene and noise planning | Approve the installation layout |
| Hotel wellness facility | Operating hours, water volume and service expectations | Duty cycle, maintenance access and spare parts | Compare with higher-capacity models if needed |
| Distributor or OEM brand | Target market, quantity, voltage, certification and packaging | Repeatable specification and documentation | Approve a sample before bulk production |
Information Needed for Accurate Sizing
- Actual water volume and tub dimensions
- Starting water temperature and target temperature
- Maximum ambient temperature
- Indoor, sheltered outdoor or exposed installation
- Expected users per day and peak users per hour
- Daily operating hours and required recovery time
- Tub material, insulation and cover use
- Hose diameter, plumbing length and installation height
- Voltage, frequency, plug type and destination country
Installation and Commissioning
- Confirm that the voltage, frequency and plug on the rating label match the installation site.
- Place the chiller on a firm, dry and level surface, then secure it against unwanted movement.
- Keep the fan, side ventilation panels and service area clear. Follow the final manual's required clearances.
- Position the unit close to the tub so hoses remain short and free from sharp bends.
- Connect the tub outlet to the chiller inlet and the chiller outlet to the tub return using the specified hoses, seals and clamps.
- Install and prime the filtration and circulation loop according to the manual. Never run the pump dry.
- Inspect all connections for leakage before connecting power.
- Start circulation, confirm stable flow and then select the target temperature.
- During the first cycle, check for leakage, restricted airflow, abnormal noise or controller fault codes.
Keep the unit away from flooding and standing water. Outdoor installation requires confirmation of the final production configuration, verified IP rating, shelter, drainage and ambient operating limits.
Maintenance Schedule
| Frequency | Recommended maintenance |
|---|---|
| Before each use | Check water level, visible water quality, leakage, hose condition and unobstructed airflow. |
| After high-traffic sessions | Remove visible debris and follow the facility's approved water-care procedure. |
| Weekly | Inspect and clean the pre-filter or strainer; wipe the enclosure and controller with a soft damp cloth. |
| Based on usage | Clean or replace the cartridge filter according to water quality and user load. |
| Monthly | Inspect hose clamps, seals, fittings, power cable, wheels and ventilation openings. |
| Before long-term storage | Disconnect power, drain the circuit, clean and dry the unit, and store it in a dry ventilated area. |
- Disconnect power before cleaning, draining or opening a service panel.
- Do not pressure-wash the enclosure.
- Do not use unapproved chemicals that may damage seals, hoses, filters or the heat exchanger.
- Commercial operators should keep a written inspection and maintenance log.
Packaging, Ordering and Delivery
The SVA-10D product size is 535 × 348 × 516 mm and the matched export-carton size is 690 × 515 × 670 mm. The net unit weight is 38 kg. Gross shipping weight, pallet quantity and loading quantity must be confirmed against the final order configuration before freight booking.
The final packing list is confirmed in the quotation and sales contract. It should identify the SVA-10D chiller, filtration parts, hoses, connectors, seals, market-specific power cable, user manual and any optional spare-parts or consumables pack.
| Commercial item | Current company baseline |
|---|---|
| Standard MOQ | 50 units for regular models |
| Customized MOQ | Confirmed according to the requested changes |
| Standard production lead time | Approximately 30-45 days after order confirmation |
| Payment terms | 50% deposit after order confirmation; 50% balance before shipment |
| Payment methods | T/T, L/C and other agreed methods |
| Standard warranty | 12 months |
Before payment, confirm packing dimensions, gross weight, units per pallet, loading quantity, Incoterm, destination documentation, spare-parts pack and shipment schedule. OEM/ODM projects should also approve logo placement, color, labels, manual language and carton artwork before bulk production.
Manufactured by a Chiller Specialist Since 2011
Foshan Springvive Equipment Co., Ltd. has manufactured cooling equipment since 2011. The company operates a 5,000+ m² facility in Foshan, Guangdong, with more than 100 team members and reports serving customers in over 40 countries.
International buyers can request technical documents, applicable certificates, operating-test evidence, user manuals, replacement-filter information, spare-parts support and OEM/ODM documentation for the exact SVA-10D configuration quoted.
Frequently Asked Questions
What water volume can the SVA-10D handle?
The correct water volume depends on starting temperature, target temperature, ambient heat, tub insulation, cover use, plumbing length and user load. Send the real project conditions for a sizing check rather than selecting only by horsepower.
How quickly can this 1HP chiller cool a plunge tub?
For the supplied calculation condition of 300 L water at 25°C ambient, cooling from 25°C to 5°C takes approximately 3.7 hours. This is a calculated reference, not a guarantee for every installation.
What temperature range does it support?
The verified rated range is 0°C–42°C (32°F–107.6°F). Confirm the final minimum setpoint, freeze protection and recommended operating limits in the supplied manual.
Does the SVA-10D provide heating as well as cooling?
Yes. The 220–240V configuration is rated at 3100W cooling and 3600W heating. Under the supplied 300 L, 25°C ambient calculation condition, heating from 5°C to 25°C takes approximately 2.7 hours.
Is this chiller suitable for commercial gyms?
It is designed for commercial recovery environments. Final suitability depends on water volume, users per hour, operating schedule, ambient conditions, required recovery time and the maintenance workflow.
Does it include filtration?
The photographed configuration includes cartridge filtration and marked inlet and outlet connections. Confirm the supplied filter model, replacement interval and spare-part number in the final quotation and manual.
Can it connect to an existing cold-plunge tub?
It can be evaluated for compatible tubs with suitable inlet and return connections and adequate circulation. Confirm hose diameter, connector type, tub height, priming method and maximum plumbing length before ordering.
Can the unit be installed outdoors?
Outdoor suitability depends on the verified IP rating, shelter, drainage, ambient limits and exposure to rain, dust or flooding. Confirm the exact production configuration before outdoor installation.
How often should the cartridge filter be changed?
The interval depends on the filter model, water quality and user load. The final manual should state cleaning and replacement intervals. Commercial facilities should keep spare cartridges in stock.
What OEM/ODM options are available?
Options can include logo placement, enclosure finish, controller language, labels, user-manual language, carton artwork, plug type, voltage and specification changes. Availability, tooling, MOQ and lead time depend on the project.
What are the MOQ and production lead time?
The current company baseline is a 50-unit MOQ for regular models and approximately 30-45 days' production after order confirmation. Customized and rush projects require a separate schedule.
What warranty is provided?
The current company baseline is a 12-month warranty. Confirm the warranty start date, exclusions, replacement-parts procedure and freight responsibility in the quotation.
What information should I send for a quotation?
Send the destination country, quantity, tub volume, starting and target temperatures, maximum ambient temperature, daily user count, operating hours, voltage, plug type, installation environment, certification needs and customization requirements.
Request an SVA-10D Project Review
Tell Springvive how and where the chiller will be used. The team can review the water volume, thermal load, operating schedule, electrical standard and customization requirements, then prepare a configuration and quotation for the project.
Cold-water safety: Cold-water exposure can place stress on the body. Users with health concerns, cardiovascular conditions or pregnancy should seek advice from a qualified healthcare professional before use. Commercial operators should provide appropriate supervision and safety procedures.
よくある質問
デザインやブランディングのカスタマイズは可能ですか?
はい、カスタムロゴ、色、パッケージ、仕様など、お客様のブランド要件に合わせた完全なOEM/ODMサービスを提供しています。
最小発注数量(MOQ)はいくつですか?
標準モデルの標準MOQは50個です。カスタマイズ製品については、具体的なMOQ要件についてお問い合わせください。
納期はどれくらいですか?
標準納期は注文確認後約30日です。緊急注文についてはご相談ください。
支払い条件はどのようになっていますか?
注文確認時に50%のデポジット、出荷前に残り50%の支払いを受け付けています。T/T、L/C、その他の支払い方法も利用可能です。
どのような保証を提供していますか?
すべての製品には製造上の欠陥をカバーする12ヶ月の保証が付いています。大口注文には延長保証オプションもございます。